Medium voltage converter
Innomotics SL150
The Innomotics SL150 cycloconverter with thyristor stacks is an optimal solution for controlling the low-speed and high-torque induction and synchronous motors. Designed as three-phase thyristor bridges in 6 or 12-pulse connections, they are robust and ideal for rolling mills, powering mine winders, conveyors, grinding mills and excavators.
Benefits at a glance
- Fewest drive components for any given power rating
Low component variety to reduce capital investment and associated costs for storage and logistics. - Compact and rugged design for extreme environments
High altitudes, temperatures and air quality, plus service friendliness for remote areas.
- Optimal configuration and operation
Integrated test routines, feedback and self-diagnostics, including thyristors, improved commissioning and tuning.
Use of standard HV cable due to the typical low switching speed of thyristors (no screened or armored cables required).
Technical data overview
| Air cooling* |
Supply voltage (V) |
Motor voltage (V) |
Power (MVA) |
|
| Single 6-pulse connection | Open connection | 1180 | 1650 | 3.2 - 9.4 |
| Star connection | 3 x 950 | 1500 | 2.9 - 8.4 | |
| Star connection | 3 x 1150 | 1650 | 3.1 - 9.2 | |
| Star connection | 3 x 1360 | 2190 | 6.3 - 8.7 | |
| 2 x 6-pulse | Open connection | 2 x 1180 | 2 x 1650 | 11.8 - 18.8 |
| Star connection | 6 x 950 | 2 x 1500 | 5.8 - 16.8 | |
| Star connection | 6 x 1360 | 2 x 2190 | 12.5 - 17.4 | |
| Series Connection 2 x 6-pulse | Star connection | 6 x 950 | 3000 | 5.8 - 16.8 |
| Star connection | 6 x 1150 | 3300 | 6.2 - 18.4 | |
| 12-pulse parallel connection | Open connection | 2 x 1180 | 1650 | 6.4 - 18.8 |
| Star connection | 6 x 950 | 1500 | 5.8 - 16.8 | |
| Star connection | 6 x 1150 | 1650 | 6.2 - 18.4 | |
| Water cooling** | Supply voltage |
Motor voltage |
Power |
|
| 12-pulse series connection | Star connection | 2 x 1310 V | 4000 V | 12 - 18 MVA |
| 2 x 6-pulse parallel connection | Star connection | 2 x 2620 V | 2 x 4000 V | 24 - 40 MVA |
* Air cooled, capable of a 200 % overload for up to 60 sec.